Технические характеристики Коммутатор Cisco DS-C9396T-96ITK9
Технические характеристики коммутатора Cisco DS-C9396T-96ITK9:
Protocols |
● Fibre Channel standards ● FC-PH, Revision 4.3 (ANSI INCITS 230-1994) ● FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996) ● FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999) ● FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997) ● FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998) ● FC-PI, Revision 13 (ANSI INCITS 352-2002) ● FC-PI-2, Revision 10 (ANSI INCITS 404-2006) ● FC-PI-3, Revision 4 (ANSI INCITS 460-2011) ● FC-PI-4, Revision 8 (ANSI INCITS 450-2008) ● FC-PI-5, Revision 6 (ANSI INCITS 479-2011) ● FC-PI-6 (ANSI INCITS 512-2015) ● FC-FS, Revision 1.9 (ANSI INCITS 373-2003) ● FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007) ● FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007) ● FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011) ● FC-FS-4 ● FC-LS, Revision 1.62 (ANSI INCITS 433-2007) ● FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011) ● FC-LS-3, Includes revision 3.53 ● FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001) ● FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004) ● FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006) ● FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010) ● FC-SW-6 ● FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001) ● FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004) ● FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007) ● FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010) ● FC-GS-7, Includes revision 10.8 ● FCP, Revision 12 (ANSI INCITS 269-1996) ● FCP-2, Revision 8 (ANSI INCITS 350-2003) ● FCP-3, Revision 4 (ANSI INCITS 416-2006) ● FCP-4, Revision 2b (ANSI INCITS 481-2011) ● FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001) ● FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003) ● FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007) ● FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011) ● FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014) ● FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014) ● FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003) ● FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006) ● FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008) ● FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010) ● FC-VI, Revision 1.84 (ANSI INCITS 357-2002) ● FC-SP, Revision 1.8 (ANSI INCITS 426-2007) ● FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012) ● FAIS, Revision 1.03 (ANSI INCITS 432-2007) ● FAIS-2, Revision 2.23 (ANSI INCITS 449-2008) ● FC-IFR, Revision 1.06 (ANSI INCITS 475-2011) ● FC-FLA, Revision 2.7 (INCITS TR-20-1998) ● FC-PLDA, Revision 2.1 (INCITS TR-19-1998) ● FC-Tape, Revision 1.17 (INCITS TR-24-1999) ● FC-MI, Revision 1.92 (INCITS TR-30-2002) ● FC-MI-2, Revision 2.6 (INCITS TR-39-2005) ● FC-MI-3, Revision 1.03 (INCITS TR-48-2012) ● FC-DA, Revision 3.1 (INCITS TR-36-2004) ● FC-DA-2, Revision 1.06 (INCITS TR-49-2012) ● FC-MSQS, Revision 3.2 (INCITS TR-46-2011) ● Fibre Channel classes of service: Class 2, Class 3, and Class F ● Fibre Channel standard port types: E, F, and B ● Fibre Channel enhanced port types: SD, ST, and TE ● FC-NVMe ● In-band management using IP over Fibre Channel (RFC 2625) ● IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338) ● Extensive IETF-standards-based TCP/IP, SNMPv3, and Remote Monitoring (RMON) MIBs |
Fibre Channel ports |
● Fixed switch form-factor with 96 SFP+ ports ● Entry-level 48-port preactivated base model ● Incremental ports ◦ 16-port upgrade license offers the option of incrementally upgrading to 64, 80, and 96 ports |
Security |
● VSAN fabric isolation ● Intelligent packet inspection at port level ● Hardware zoning by Access Control Lists (ACLs) ● Fibre Channel Security Protocol (FC-SP) switch-to-switch authentication ● FC-SP host-to-switch authentication ● RBAC using RADIUS, TACACS+ or LDAP Authentication, Authorization, and Accounting (AAA) functions ● Secure FTP (SFTP) ● Secure Shell Version 2 (SSHv2) ● Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES) ● Control-plane security ● Cisco TrustSec payload encryption ● Secure Boot and Anti-counterfeit technology |
Performance |
● Port speed: 4/8/16/32-Gbps autosensing with 32 Gbps of dedicated bandwidth per port ● Aggregate bandwidth of 3 Tbps end-to-end full duplex ● Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group ● Port groups: 6 port groups of 16 ports each ● Port channel: Up to 16 load-balanced physical links grouped in one port channel |
Diagnostics |
● Power-On-Self-Test (POST) diagnostics ● Online Health Management System (OHMS) diagnostics ● Internal loopbacks ● SPAN ● Fibre Channel traceroute ● Fibre Channel ping ● Fibre Channel debug ● Cisco Fabric Analyzer ● Syslog ● Port-level statistics ● Link Diagnostics (E-port and F-port links) ● Read Diagnostic Parameter |
Serviceability |
● Configuration file management ● Call Home ● Port beaconing ● Link Cable beacon ● System LEDs ● SNMP traps for alerts |
Reliability and availability |
● Cisco In-Service Software Upgrade (ISSU) ● Hot-swappable, dual redundant power supplies ● Hot-swappable fan tray with switch integrated temperature and power management ● Hot-swappable SFP+ optics ● Hot swappable port expansion module ● Stateful process restart ● Any port configuration for port channels ● Fabric-based multi pathing ● Per-VSAN fabric services ● Port tracking ● VRRP for management IP interface ● FEC with HBA ports ● Buffer-to-buffer state change notification with HBA ports |
Network management |
● Management access through 2 out-of-band 10/100/1000 Mbps Ethernet ports ◦ mgmt0: 10/100/1000BASE-T port ◦ mgmt1: 1/10G SFP+ port # ● RS-232 serial console port ● USB power-on auto-provision port ● Access protocols ● Command-Line Interface (CLI) using the console and Ethernet port ● SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access ● Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S) ● NX-API for restful access via HTTPS ● Distributed device alias service ● Network security ● Per-VSAN Role-Based Access Control (RBAC) using LDAP, RADIUS and TACACS+-based Authentication, Authorization, and Accounting (AAA) functions ● SFTP ● SSHv2 implementing AES ● SNMPv3 implementing AES ● Cisco Data Center Network Manager |
Programming interfaces |
● Scriptable CLI ● Cisco Prime DCNM web services API ● NX-API restful interfaces ● On-board Python interpreter ● Cisco Embedded Event Manager ● Cisco NX-OS Software scheduler |
Physical dimensions (H x W x D) and weight |
● Dimensions: 3.39 x 17.42 x 22.28 in. (8.61 x 44.25 x 56.59 cm), 2RU ● Rack-mountable in standard 19-inch Electronic Industries Alliance (EIA) rack ● Weight of fully configured chassis: 41.62 lb (18.88 kg) |
Power |
● 80 Plus Platinum certified power supplies ● Power supply ◦ 1200W AC/ HVAC/ HVDC Bidirectional airflow (2 per switch) ◦ Power grid redundancy (1+1) ● Two power cords ◦ Standard CAB-HVAC-C14-2M IEC C14 to Saf-d-grid connector on the power supply receptacle ◦ See Table 6 for configurable AC power cords that connect to AC sockets specific to regions ● AC input: 90V to 305V ● DC input: 192V to 400V ● Frequency: 50 to 60 Hz (nominal) ● Typical power consumption ◦ 246W for Idle 96-port switch with (1+1) PSU redundancy without optics modules ◦ 330W for 96-port switch with 48 32G optics modules under typical conditions ◦ 555W for 96-port switch with 96 32G optics modules under typical conditions ● Airflow ◦ 2 fan trays as standard configuration ◦ Back to front (toward ports) using port-side exhaust fans ◦ Front to back (inward from ports) using port-side intake fans ◦ Maximum 255 Cubic Feet per Minute (CFM) ◦ Nominal 110 CFM (25C) |
Temperature range |
● Temperature, ambient operating: ◦ 32° to 104°F (0° to 40°C) ◦ Temperature, ambient nonoperating and storage: -40° to 158°F (-40° to 70°C) ● Relative humidity, ambient (noncondensing) operating: 10 to 90% ● Relative humidity, ambient (noncondensing) non-operating and storage: 10 to 95% ● Altitude, operating: -197 to 6500 ft (-60 to 2000m) |
Approvals and compliance |
● Safety compliance ● CE Marking ● UL 60950 ● CAN/CSA-C22.2 No. 60950 ● EN 60950 ● IEC 60950 ● TS 001 ● AS/NZS 3260 ● IEC60825 ● EN60825 ● 21 CFR 1040 ● EMC compliance ● FCC Part 15 (CFR 47) Class A ● ICES-003 Class A ● EN 55022 Class A ● CISPR 22 Class A ● AS/NZS 3548 Class A ● VCCI Class A ● EN 55024 ● EN 50082-1 ● EN 61000-6-1 ● EN 61000-3-2 ● EN 61000-3-3 |
Fabric services |
● Name server ● Registered State Change Notification (RSCN) ● Login services ● Fabric Configuration Server (FCS) ● Broadcast ● In-order delivery |
Advanced functions |
● VSAN ● IVR ● Port channel with multipath load balancing ● Flow-based and zone-based QoS |
Хотите заказать сетевое оборудование?
Описание Коммутатор Cisco DS-C9396T-96ITK9
Коммутатор Cisco DS-C9396T-96ITK9 и другое сетевое оборудования бренда Cisco доступны в интернет-магазине Csystems по низким ценам. Если вы хотите купить Коммутатор Cisco DS-C9396T-96ITK9 в интернет-магазине Csystems, предварительно уточните наличие. Вы можете получить сетевое оборудование удобным для Вас способом, для этого свяжитесь с нами по контактам указанным на сайте.
Преимущества работы с нами
- Высокий уровень корпоративной репутации
- Собственный склад, с наличием основных позиций
- Собственная логистика, с возможностью поставки любого товара
- Бесплатная доставка до Вашей двери (Яндекс доставка при заказе от 50 000 руб)
- Сервисный центр по ремонту и замене неисправного оборудования
- Индивидуальный подход к каждому клиенту, решение любых финансовых вопросов
- Возможность принимать платежи в криптовалюте и от зарубежных партнеров
- Рассрочка
- Возможность отгрузить оборудование в любой точке мира
- Выкуп и утилизация оборудования
- Интеграция и внедрение любых решений для вашего предприятия
- Трейд-ин
- Техподдержка 24/7